RUGGEDCOM ROX II
CLI User Guide
Parameter
interfaces clearstatistics [ ddsName | t1e1Name |
t3e3Name ] name
services dhcpserver show-active-leases
Section 2.6.9.4
Administration Commands
Operational mode provides commands for performing device administration tasks.
Parameter
admin acknowledge-all-alarms
admin clear-all-alarms
admin delete-all-ssh-known-hosts
admin delete-ssh-known-hosts
admin restore-factory-defaults
admin reboot
admin restore-factory-defaults
admin set-system-clock time YYYY-MM-DD HH:MM:SS
admin shutdown
admin software-upgrade decline-upgrade
admin software-upgrade launch-upgrade
admin software-upgrade rollback-reboot
maint-login
Administration Commands
Description
Clears statistics for the specified WAN interface. Use tab completion
to display a list of available WAN interfaces.
Displays active DHCP leases.
Description
Acknowledges all system alarms.
Clears all system alarms.
Deletes the list of known hosts.
Deletes the host entry from the list of known hosts.
Restores the factory default configuration and settings, but does not
erase any files you have saved on the device.
Reboots the device.
Restores the factory default configuration and settings, but does not
erase any files you have saved on the device.
Sets the date and time on the device. To specify just the date, type
the date in the format YYYY-MM-DD. To specify just the time, type
the time in the format HH:MM:SS. To specify both date and time,
enclose the string in quotation marks and type the date and time in
the format "YYYY-MM-DD HH:MM:SS".
NOTE
When setting the time, specifying seconds seconds
(SS) is optional.
Shuts down the device.
For more information on shutting down the device, refer to
Section 3.4, "Shutting Down the Device"
Cancels (or declines) a recent software upgrade that is waiting for a
reboot to the upgraded partition.
Launches an upgrade in the alternate partition.
Boots to a previous software release on the alternate partition.
CAUTION!
Configuration hazard – risk of data loss/corruption.
Maintenance mode is provided for troubleshooting
purposes and should only be used by Siemens Canada
Ltd. technicians. Maintenance mode is provided for
Chapter 2
Using RUGGEDCOM ROX II
37