Operating sequence for loading HW config to the NCU
1. Change from "NetPro" to "HW Config".
2. Click the "Download to module" button.
The two communication partners are automatically marked in the "Select target module"
dialog
3. Confirm the load into the module with "OK".
4. Confirm the following dialog boxes initially with "OK" and then "No" for the query "... Should
the module be started now (restart)?".
Note
Loading the HW config to the NCU is only possible via the Ethernet interface.
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
5.8 Configuring a network (NetPro) for PG/PC
PLC commissioning