Requirements for commissioning
3.1
General prerequisites
Preconditions for components involved
The complete system is connected mechanically and electrically, and has been verified in the
following points:
● All ESD measures are observed for the design of the components.
● All screws are tightened with their prescribed torque.
● All connectors are plugged correctly and locked/screwed.
● All components are grounded and connected to shields.
● The load capacity of the central power supply is taken into account.
Limit values
All components are dimensioned for defined mechanical, climatic and electrical environmental
conditions. No limit value may be exceeded, neither during operation, nor during transportation.
Special attention must be paid to the limit values:
● Power supply conditions
● Pollution burden
● Function-impairing gases
● Ambient environmental conditions
● Storage/transport
● Shock stressing
● Vibration stressing
● Ambient temperature
You can find further details in the following manuals:
● Structure of the drive components: SINAMICS S120 Booksize Power Units
support.industry.siemens.com/cs/ww/en/view/109766188) Equipment Manual
● Interfaces at the control system: SINUMERIK 840D sl Equipment Manual NCU 7x0.3B PN
(https://support.industry.siemens.com/cs/de/en/view/99922219)
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
3
(https://
31