PLC commissioning
5.2 Creating a SIMATIC S7 project (PROFIBUS)
3. Double-click the <Hardware> symbol.
The HW Config for introducing required hardware is started.
4. In the menu, select "View" > "Catalog". The catalog with the modules is displayed.
The user interface of the "HW Config" hardware configuration shows the following details:
– Station window:
– Hardware catalog
54
①
Station window:
②
Details
③
Hardware catalog
The station window is split. The upper part displays the structure of the station
graphically, and the lower part provides a detailed view of the selected module.
This catalog also contains the SINUMERIK NCU that you need for configuring the
hardware.
CNC Commissioning: NC, PLC, Drive