11.2.1
How to transfer data within the controller
Transfer data within the control
NOTICE
Protection of the machine
For safety reasons, the machine and setting data should only be transferred when the enable
is locked.
Procedure:
1. Select the "Transfer data within the control" option.
2. Select the source data in the data structure and confirm with "OK".
3. In the drop-down list, select an object, e.g. a different axis or a different drive object, to which
you want to transfer the data and confirm with "OK".
4. Observe the safety instructions and check the enable signals at the machine and the drive.
5. For drive data, the "Load" softkey is used to transfer the data to the target object.
11.2.2
To save and load data
Save data to a file
Procedure:
1. Select the "Save data to a file" option.
2. In the data structure, select the data that you want to save to a file and confirm with "OK".
3. Select as the storage location, a directory or a USB storage medium and enter a name.
Note
SINAMICS parameters
An ASCII file (*.TEA) is always generated when saving.
Three files of the following type are generated when saving the drive data:
● A binary file (*.ACX) that cannot be read.
● An ASCII file (*.TEA) that can be read or edited in the ASCII editor.
● A log file (*.log) that contains message texts (error situation) or is empty (successful
storage).
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
Saving and managing data
11.2 Managing data
351