Siemens SINUMERIK 840D sl Commissioning Manual page 120

Cnc commissioning: nc, plc, drive
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Commissioning NC-controlled drives
6.3 Guided commissioning of SINAMICS drives
3. Select "Next step >".
The power data of the infeed is configured here:
– When the checkbox is selected, the line/DC link identification is activated once the infeed
– Enter the device connection voltage: This is the basis for monitoring the line voltage
– The actual line frequency for the infeed is determined automatically.
– In parameters p0284, p0285, set a threshold above which an alarm is triggered (default
120
pulse enable has been activated (p3410). The infeed then switches to operational mode.
Note
DC link identification
If the line supply environment changes or the components on the DC link change (e.g.
after setting up the equipment at the customer site or after expanding the drive group),
the checkbox must be set again: Hence the "Power data" softkey in the overview in order
to restart the line/DC link circuit identification.
If p3410 = 5 is saved in the commissioning archive, then the line/DC link identification
starts automatically once the drive data is input into the archive.
Only then can it be guaranteed that the infeed operates with the optimum controller
settings.
(p0281 - p0283), whereby an alarm is triggered in the case of an overshoot or
undershoot. (Alarm threshold and shutdown threshold). The actual line voltage is
determined automatically and the adjustment is made based on this value.
setting of the monitoring: 45 Hz to 65 Hz).
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents