4. The NCU module with SINAMICS S120 is inserted into the HW Config.
Note
With the <F4> key and confirmation of the prompt regarding "Reorganization", you can
reorganize the display in the station window.
5. Confirm with "OK".
Next, specify the properties for the Ethernet interface.
Operating sequence for Ethernet interface
Note
Use service interface X127 when commissioning the PLC. The Ethernet interface does not
have to be configured. This interface is already initialized with the IP address 192.168.215.1
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
5.2 Creating a SIMATIC S7 project (PROFIBUS)
PLC commissioning