Trace result
The following graphic is displayed after the trace has been stopped:
Select the "≪ Back" softkey to save the session.
Select what you wish to save with the "Save trace >" softkey: Variables and settings with or
without recorded values (graphic).
The name of the session and target directory can be changed.
6.6.3
Example: Zooming in/zooming out
Trace view: Zoom
Procedure:
1. Select the "Fit all" softkey to scale all of the curves.
2. Press the following keys to select curve 1 (position actual value measuring system 1) and
curve 2 (position setpoint) for the next steps:
3. Select the "Zoom >" softkey.
4. Select the "Fit overlaid" softkey to precisely place both curves one above the other. Each
curve is individually scaled using the "Fit separated".
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
Commissioning NC-controlled drives
6.6 Diagnostics → Trace
167