Terminal
X132.11
X132.12
X132.13
X132.14
In the "pre-assigned" column, the signals for which the associated SINAMICS parameters are set when
configuring a SINAMICS device are marked with "x".
6.2.4
X142 terminal assignment
Terminal
X142.1
X142.2
X142.3
X142.4
X142.5
X142.6
X142.7
X142.8
X142.9
X142.10
X142.11
X142.12
X142.13
X142.14
6.2.5
Terminal assignment NX1x.3
The table lists the assignments of the terminals on an NX1x.3 for the X122 terminal strip.
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
Signal name
Function
Ground for terminals 9, 10, 12, 13
DI/DO 14
Input 2. Operating condition OFF2 drives
Input, external zero mark 3
Input probe 2 - central measurement
Input probe 2 - distributed measurement
Infeed, control line contactor
DI/DO 15
Input 2. Operating condition OFF2 drives
Input, external zero mark 4
Input probe 2 - central measurement
Input probe 2 - distributed measurement
Ground for terminals 9, 10, 12, 13
Signal name
Function
---
Reserved
---
Reserved
DI0
NC input
DI1
NC input
Ground for terminals X142.3, 4, 6, 7, 9, 10, 12, 13
DI2
NC input
DI3
NC input
Ground for terminals X142.3, 4, 6, 7, 9, 10, 12, 13
DO4
NC output
DO5
NC output
Ground for terminals X142.3, 4, 6, 7, 9, 10, 12, 13
DO6
NC output
DO7
NC output
Ground for terminals X142.3, 4, 6, 7, 9, 10, 12, 13
Commissioning NC-controlled drives
6.2 Terminal assignment
Pre-assignment
$A_IN[1]
$A_IN[2]
$A_IN[3]
$A_IN[4]
$A_OUT[1]
$A_OUT[2]
$A_OUT[3]
$A_OUT[4]
Pre-assign‐
ment
---
---
---
---
---
---
---
---
---
---
---
fixed
fixed
---
fixed
fixed
---
fixed
fixed
---
fixed
fixed
---
109