11.02
10930
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10931
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10932
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10933
Parameters:
Definitions:
Reactions:
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 interpolation type not allowed in stock removal contour
%1 = Channel number
%2 = Block number, label
The following types of interpolation are allowed in the contour program for stock removal:
G00, G01, G02, G03, CIP, CT
- Local alarm reaction.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
In the contour subroutine, program only path elements that consist of straight lines and
arcs.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 incorrect stock removal contour
%1 = Channel number
%2 = Block number, label
The following errors occurred in the subroutine for the contour during stock removal:
• Full circle
• Overlapping contour elements
• Wrong start position
- Local alarm reaction.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
The errors listed above must be corrected in the subroutine for the stock removal contour.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 preparation of contour has been restarted
%1 = Channel number
%2 = Block number, label
The first contour preparation/contour decoding run must be terminated with EXECUTE.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- NC Start disable in this channel.
Program the keyword EXECUTE to terminate the contour preparation in the part program
before again calling up contour segmentation (keyword CONTPRON).
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 contour program does not contain enough contour blocks
%1 = Channel number
%2 = Block number, label
The contour program contains:
• Less than 3 contour blocks with CONTPRON
• No contour blocks with CONTDCON
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- NC Start disable in this channel.
1 Alarms