1 Alarms
Remedy:
Program Continuation:
12430
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12440
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12450
Parameters:
Definitions:
Reactions:
1-140
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. The symbol to
be created or the target of program jumps (label) must conform to the system specifica-
tions, that means the name must begin with 2 letters (but the 1st sign must not be "§") and
may be up to a maximum of 32 characters.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 specified index is invalid
%1 = Channel number
%2 = Block number, label
In specifying an array index (in the array definition) an index was used that is outside the
permissible range.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Specify array
index within the permissible range. Value range per array dimension: 1 - 32 767.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 maximum number of formal arguments exceeded
%1 = Channel number
%2 = Block number, label
In the definition of a procedure (a subroutine) or in an EXTERN instruction, more than 127
formal parameters have been specified.
Example: PROC ABC (FORMPARA1, FORMPARA2, ... ... FORMPARA127,
FORMPARA128, ...) EXTERN ABC (FORMPARA1, FORMPARA2, ... ...
FORMPARA127, FORMPARA128, ...)
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. A check must
be made to determine whether all parameters really have to be transferred. If so, the for-
mal parameters can be reduced by using global variables or R parameters, or by grouping
together parameters of the same type to form an array and transfer them in this form.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 label defined twice
%1 = Channel number
%2 = Block number, label
The label of this block already exists.
If the NC program is compiled off-line, the entire program is compiled block for block. Dur-
ing this procedure all multiple labels are recognized; this is not always the case with on-
line compilation. (Only the actual program run is compiled here, i.e. program branches
that are not passed through in this run are disregarded and could therefore contain pro-
gramming errors).
- Alarm display.
- Interface signals are set.
- Correction block
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition