1 Alarms
Program Continuation:
17192
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17193
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-260
If the program is incorrect - T5 programmed instead of T55 - the current block can be cor-
rected with a correction block; i.e. if only M06 is entered, you can correct the block with
T55 M06. The incorrect T5 line remains in the program until it is terminated by a RESET
or end of program.
In complex program structures with indirect programming, it may not be possible to cor-
rect the program. In this case, you can only intervene locally with an overstore block - with
T55 in the example. If the data block is missing, create one. You can do this by download-
ing the data block of the tool with all the defined D numbers onto the NCK (via MMC with
overstore), program the T command with overstore, and continue the program.
Clear alarm with NC START or RESET key and continue the program.
TO unit %1 invalid tool designation of '%2', duplo no. %3. No more replacement
tools possible in '%4'.
%1 = TO unit
%2 = Tool identifier
%3 = Duplo number
%4 = Group identifier
The tool with the specified tool identifier, duplo number cannot accept the group identifier.
Reason: The maximum number of replacement tools allowed has already been defined.
The name allocation causes the tool to be reallocated to a tool group which already con-
tains the maximum number of replacement tools allowed on this machine.
- Alarm display.
- Interface signals are set.
Use fewer replacement tools or request a different maximum setting from the machine
manufacturer.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 the active tool is no longer on toolholder no./spindle no. %3,
program %4
%1 = Channel number
%2 = Block number, label
%3 = Toolholder no., spindle no.
%4 = Program name
The tool at the specified toolholder/spindle at which the last tool change was carried out
as master toolholder or master spindle, has been replaced.
Example:
N10 SETHTH(1)
N20 T="Wz1" ; Tool change at master toolholder 1
N30 SETMTH(2)
N40 T1="Wz2" ; Toolholder 1 is only a secondary toolholder.
Changing the tool does not result in correction deselection.
N50 D5; New correction selection. At present, there is no active tool which D can refer to,
i.e. D5 refers to T no. = 0, which results in zero correction.
- Interface signals are set.
- Alarm display.
• Modify program:
• Set desired spindle as master spindle or toolholder as master toolholder.
• Then, if required, reset master spindle or master toolholder.
Clear alarm with the Delete key or NC START.