1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
14036
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14037
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14038
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14039
Parameters:
Definitions:
1-162
With involute interpolation, the start point of the involute must be outside the basic circle.
The programmed center point or radius must be adapted accordingly.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: end point invalid
%1 = Channel number
%2 = Block number, label
With involute interpolation, the end point of the involute must be outside the basic circle.
The programmed center point / radius or end point must be adapted accordingly.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: radius invalid
%1 = Channel number
%2 = Block number, label
With involute interpolation, the programmed radius of the basic circle must be greater
than zero.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute not definable: end point error
%1 = Channel number
%2 = Block number, label
The programmed end point does not lie on the involute defined by the start point, radius
and center point of the basic circle. The deviation of the effective end radius from the pro-
grammed value is greater than the permissible value specified in MD
INVOLUTE_RADIUS_DELTA.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: end point programmed several times
%1 = Channel number
%2 = Block number, label
With involute interpolation, either the end point with the geometry axis identifiers or the
angle of rotation with AR=value can be programmed. Simultaneous programming of end
point and angle of rotation in one block is not allowed, since the end point can thus not be
defined exactly.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition