1 Alarms
Remedy:
Program Continuation:
4346
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4347
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4350
Parameters:
Definitions:
Reactions:
1-56
Set a valid transformation chain.
Clear alarm with the RESET key. Restart part program
Channel %1 invalid geoaxis assignment in machine data %2[%3]
%1 = Channel number
%2 = Name of machine data
%3 = Transformation number
Machine data TRAFO_GEOAX_ASSIGN_TAB_X contains an invalid entry. The following
causes for the error are possible:
• The entry references a channel axis which does not exist.
• The entry is zero (no axis) but the transformation needs the relevant axis as a geometry
axis.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Correct the entry in TRAFO_GEOAX_ASSIGN_TAB_X or TRAFO_AXES_IN_X.
Clear alarm with the RESET key. Restart part program
Channel %1 invalid channel axis assignment in machine data %2[%3]
%1 = Channel number
%2 = Name of machine data
%3 = Transformation number
Machine data TRAFO_AXIS_IN_X contains an invalid entry. The following causes for the
error are possible:
• The entry references a channel axis which does not exist.
• The entry is zero (no axis) but the transformation needs the relevant axis as a channel
axis.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Correct the entry in TRAFO_AXES_IN_X.
Clear alarm with the RESET key. Restart part program
Channel %1 axis identifier %2 machine data %3 not consistent with machine data
%4
%1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = String: MD identifier
MD 32410 JOG_AND_POS_JERK_ENABLE (jerk limitation) and MD 35240
ACCEL_TYPE_DRIVE (acceleration reduction) have been defined as the initial setting for
an axis. However, the two functions cannot be activated at the same time for one axis.
- Alarm display.
- Interface signals are set.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved