Siemens SINUMERIK 840D Series Diagnostics Manual page 466

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Program Continuation:
300007
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300008
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-466
3) Check whether all drive bus connectors have correctly snapped into place and that the
bus terminator is connected.
4) If you have not been able to detect an error by now, the module is defective.
• Replace the module.
Switch control OFF - ON.
Axis %1 drive %2 not present or inactive
%1 = NC axis number
%2 = Drive number
In the axis-specific machine data 30110 CTRLOUT_MODULE_NR (this specifies at which
drive module the speed setpoint is output) and MD 30220 ENC_MODULE_NR (this spec-
ifies the drive module which outputs the encoder actual value for the position control)
there is a drive logic number that does not occur in the NCK MD 13010
DRIVE_LOGIC_NR and the machine data 30240 ENC_TYPE and MD 30130
CTRLOUT_TYPE are set to "1".
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Check the setpoint/actual
value assignment in the axis-specific MD 30110 CTRLOUT_ MODULE_NR and MD
30220 ENC_MODULE_NR and the drive logic number in the NCK MD 13010
DRIVE_LOGIC_NR and bring these into agreement.
Switch control OFF - ON.
Axis %1 drive %2 measuring circuit %3 is not available
%1 = NC axis number
%2 = Drive number
%3 = Measuring circuit number
In the axis-specific MD 30230 ENC_INPUT_NR [e]=E (e ... encoder index - the position
control works with this encoder, E ... encoder number - encoder connector selection on
the drive module), an encoder connector (1 or 2) was selected, to which no encoder is
connected.
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Configure MD 30230
ENC_INPUT_NR [e] according to the encoder connector used or plug the encoder cable
onto the other connector.
If the encoder used corresponds to the input in the MD, there is a hardware fault on the
drive module. Replace the module!
Switch control OFF - ON.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents