Siemens SINUMERIK 840D Series Diagnostics Manual page 465

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Remedy:
Program Continuation:
300005
Definitions:
Reactions:
Remedy:
Program Continuation:
300006
Parameters:
Definitions:
Reactions:
Remedy:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Please inform the authorized personnel/service department.
Select MD 13010 DRIVE_LOGIC_NR and search for the drive logic number that is indi-
cated in the alarm text. The location index number + 1 results in the associated rack loca-
tion number. The FDD/MSD module belonging to this location is determined by the
configuration in MD 13040 DRIVE_TYPE for the same location index.
FDD: identifier 1, MSD: identifier 2.
Switch control OFF - ON.
At least one module found on drive bus that has not been configured
At bus initialization at least one module was detected which did not have a drive number,
which amounts to one too many. Since all (!) modules on the drive bus must be correctly
initialized, all modules therefore also have to be accordingly specified in the machine
data.
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Check machine data; with
the NCK MD 13000 DRIVE_IS_ACTIVE a drive that is not yet in use but exists on the bus
can be declared as inactive. Inactive drives do not need installation and start-up or drive
data.
Switch control OFF - ON.
Module with drive number %1 has not been found on drive bus
%1 = Drive number
Not all of the drives stated in MD $MN_DRIVE_LOGIC_NR could be found on the drive
bus. You can find the associated module in the configuration display via the displayed
drive number.
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Perform the following checks:
1) Using the configuration display or the associated machine data, check whether the
number and type (1-axis or 2-axis) of the modules match your bus setup.
2) Check whether the red LED is illuminated on the displayed drive module. If this is not
the case, then usually the module does not have any power.
• Check the connections of the ribbon cable running from your I/RF or monitoring unit to
the module.
• If after switching on the I/RF or monitoring unit, no LED of a module which is connected
to it is illuminated, then check the I/RF or monitoring unit and, if required, replace the
ribbon cable.
• With a multi-tier installation where the power is switched on at different times, an error
message can also mean that one tier has been switched on too late (current permissi-
ble time 10 seconds). If possible, switch on the second tier at the same time.
1 Alarms
1-465