11.02
22051
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
22052
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
22053
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %3 spindle %2 reference mark not found
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
When referencing, the spindle turned through a greater distance than given in the axis-
specific machine data 34060 REFP_MAX_MARKER_DIST, without receiving a reference
mark signal. The check is performed for spindle positioning with SPOS or SPOSA when
the spindle has not previously run with speed control (S=...).
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
- If the axis is a single axis when this alarm is triggered, the alarm is only effective for this
axis (not effective for e.g. the channel or mode group)
Please inform the authorized personnel/service department. Check and correct the
machine data 34060 REFP_MAX_MARKER_DIST. The value entered states the distance
in [mm] or [degrees] between 2 zero markers.
Clear alarm with the RESET key. Restart part program
Channel %1 block %3 spindle %2 no standstill on block change
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
The displayed spindle has been programmed as spindle or as axis even though a posi-
tioning operation is still running from the previous block (with SPOSA ... spindle position-
ing beyond block limits).
Example:
N100 SPOSA [2] = 100
:
N125 S2 = 1000 M2 = 04 ; Error, if spindle S2 from block N100 is still running!
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Before programming the spindle/axis again using the SPOSA instruction, a WAITS com-
mand should be activated in order to wait for the programmed spindle position.
Example:
N100 SPOSA [2] = 100
:
N125 WAITS (2)
N126 S2 = 1000 M2 = 04
Clear alarm with the RESET key. Restart part program
Channel %1 block %3 spindle %2 reference mode not supported
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
In the case of SPOS/SPOSA with an absolute encoder, only the referencing mode
ENC_REFP_MODE = 2 is supported! SPOS/SPOSA does not support
ENC_REFP_MODE = 6 at all!