Siemens SINUMERIK 840D Series Diagnostics Manual page 34

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
4028
Definitions:
Reactions:
Remedy:
Program Continuation:
4029
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4030
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4031
Parameters:
Definitions:
1-34
Notice! The axial MDs of the axes of the axis containers were matched.
Note for the user, that the machine data of the axis were matched in the axis containers.
- Alarm display.
None
Clear alarm with the RESET key. Restart part program
Notice: the axial MDs in axis container %1 will be matched on the next power-up
%1 = Axis container number
Message to the user indicating that the machine data of the axes in the axis container will
be matched on the next power-up. An axis container allows axes to be exchanged
between channels and NCUs. To ensure that no conflicts arise, the axes within the same
axis container must have a similar behavior. The first axis in the axis container determines
which machine data have to be the same for the other axis in the axis container.
- Alarm display.
None
Clear alarm with the Delete key or NC START.
Channel %1 axis identifier missing in machine data %2[%3]
%1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array index
An axis identifier is expected for the displayed MD in accordance with the axis configura-
tion in the MD 20070 AXCONF_MACHAX_USED and 20050
AXCONF_GEOAX_ASSIGN_TAB.
- Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check axis configuration and
enter the missing identifier into the MD or, should the axis not exist, specify for this chan-
nel axis the machine axis 0 in the channel-specific MD 20070
AXCONF_MACHAX_USED. If this concerns a geometry axis that is not to be used (this
applies only for 2-axis machining, e.g. on lathes), then channel axis 0 must be entered
additionally in the channel-specific MD 20050 AXCONF_GEOAX_ASSIGN_TAB.
Switch control OFF - ON.
Channel %1 link axis %2 defined for more than one channel in machine data %3
%1 = Channel number
%2 = Index: Axis number for logical axis assignment
%3 = String: MD identifier
Occurs only with an NCU link system. The specified axis was defined several times or in
several channels in machine data $MC_AXCONF_MACHAX_USED. If an axis is to be
defined in several channels, a master channel must be assigned to the axis with the axial
machine data $MA_AXCONF_ASSIGN_MASTER_CHAN. This error can only occur with
an NCU link axis. The cause of a definition error can also be an NCU link communication
failure. The link communication failure must be indicated separately by further alarms.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved