11.02
Remedy:
Program Continuation:
12230
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12240
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12250
Parameters:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
In the window for the alarm message, the first characters of the binary constant are
always displayed although the surplus bit might not be located until further on. Therefore,
the complete binary constant must always be checked for an incorrect value.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 hexadecimal constant %3 in string too long
%1 = Channel number
%2 = Block number, label
%3 = Hexadecimal constant
A string can also contain bytes that do not correspond to a character that can be entered
or one that is available on a keyboard with a minimized number of keys. These characters
can be input as binary or hexadecimal constants. They may occupy up to 1 byte each only
- therefore be < 256, e.g.
N10 DEF STRING[2] OTTO=" 'HCA' 'HFE' "
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
In the window for the alarm message, the first characters of the binary constant are
always displayed although the surplus bit might not be located until further on. Therefore,
the complete hexadecimal constant must always be checked for an incorrect value.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 tool orientation %3 defined repeatedly
%1 = Channel number
%2 = Block number, label
%3 = Text
Only one tool orientation can be programmed per DIN block. This can either be defined
via the 3 Euler angles, or the end points of the axes, or through direction vectors.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Since the tool orientation can be set in 3 different ways, the most advantageous should be
selected. For this type of specification, the addresses and value assignments must be
programmed and all other orientation parameters must be removed.
Axis end points (additional axes): A, B, C axis identifiers Euler angles: A2, B2, C2 Direc-
tion vectors: A3, B3, C3
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 nested macro %3 not possible
%1 = Channel number
%2 = Block number, label
%3 = Source string