Siemens SINUMERIK 840D Series Diagnostics Manual page 297

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
20149
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20150
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20160
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20170
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 motion synchronous action: illegal index
%1 = Channel number
%2 = Block number
An invalid index was used for access to a variable in motion synchronous action.
Example: ... DO $R[$AC_MARKER[1]] = 100
This error occurs if the value of marker 1 is greater than the maximum permissible R
parameter number.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Use a valid index.
Clear alarm with the RESET key. Restart part program
Channel %1 tool management: PLC terminates interrupted command
%1 = Channel number
Indication that the PLC has terminated an interrupted command (with alarm output) from
the tool management - tool change.
- Alarm display.
- Interface signals are set.
For information only.
Clear alarm with the Delete key or NC START.
Channel %1 tool management: PLC can terminate only incorrectly aborted com-
mands
%1 = Channel number
Indication that the PLC wanted to interrupt an active command from the tool management
(tool change); or that there is no command active for abort. NCK refuses because the
channel status is either 'active' (abort is then not allowed), or 'reset' (then there is nothing
to abort).
- Alarm display.
- Interface signals are set.
For information only.
Clear alarm with the Delete key or NC START.
Channel %1 machine data $AC_FIFO invalid
%1 = Channel number
The structure of the FIFO variable $AC_FIFO - $AC_FIFO10 determined by the machine
data $MC_NUM_AC_FIFO, $MC_START_AC_FIFO, $MC_LEN_AC_FIFO and
$MC_MODE_AC_FIFO cannot be stored in the R parameter field defined in
$MC_MM_NUM_R_PARAM.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
Please inform the authorized personnel/service department. Increase the number of the R
parameters or reduce the FIFO elements.
$MC_MM_NUM_R_PARAM = $MC_START_AC_FIFO + $MC_NUM_AC_FIFO x
($MC_LEN_AC_FIFO + 6)
Switch control OFF - ON.
1 Alarms
1-297

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents