11.02
12590
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12600
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12610
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12620
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 global user data cannot be created
%1 = Channel number
%2 = Block number, label
The number of global user data blocks is defined in machine data 18118
MM_NUM_GUD_MODULES.
Here, _N_SGUD_DEF corresponds to block 1, _N_MGUD_DEF corresponds to block 2,
_N_UGUD_DEF corresponds to block 3, _N_GUD4_DEF corresponds to block 4 etc.
In the directory _N_DEF_DIR there is a file with definitions for global user data the block
number of which is greater than the number of blocks given in the MD.
- Alarm display.
- Interface signals are set.
- Correction block
Please inform the authorized personnel/service department. Increase machine data
18118 MM_NUM_GUD_MODULES.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid line checksum
%1 = Channel number
%2 = Block number
On processing an INI file or when executing a TEA file, an invalid line checksum has been
detected.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Correct INI file or correct MD and create new INI file (via "upload").
Switch control OFF - ON.
Channel %1 block %2 accessing single character with call-by-reference parameter
not possible %3
%1 = Channel number
%2 = Block number, label
%3 = Source string
An attempt has been made to use a single character access for a call-by-reference
parameter.
- Alarm display.
- Interface signals are set.
- Correction block
Temporarily store single characters in user-defined CHAR variable and transfer this.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 accessing this variable as single character not possible
%1 = Channel number
%2 = Block number, label
%3 = Source string
The variable is not a user-defined variable. The single character access is only allowed
for user-defined variables (LUD/GUD).
- Alarm display.
- Interface signals are set.
- Correction block