Siemens SINUMERIK 840D Series Diagnostics Manual page 198

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
14757
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14758
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14759
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14760
Parameters:
Definitions:
Reactions:
1-198
Channel %1 block %2 motion synchronous action and wrong type
%1 = Channel number
%2 = Block number, label
Programmed combination between action and type of motion synchronous action is not
allowed.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 programmed value not available
%1 = Channel number
%2 = Block number, label
The synchronous variables $AA_LOAD, $AA_TORQUE, $AA_POWER and $AA_CURR
are available only for the 611D drive. They are activated by the machine data MDC 36730
DRIVE_SIGNAL_TRACKING. The system variable $VA_IS: Safe Actual Position is avail-
able only if the machine data $MA_SAFE_FUNCTION_ENABLE has been set and the
option $ON_NUM_SAFE_AXES has been set to a sufficient size.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify program or machine data.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 motion synchronous action and wrong axis type
%1 = Channel number
%2 = Block number, label
When there are several feeds, a spark-out time, or a retraction stroke for path motions, at
least one GEO axis must be programmed. If the block also contains synchronous axes
and there are several feeds, the feedrate for the synchronous axes is matched implicitly.
No retraction stroke takes place for synchronous axes. However, after retraction stroke or
spark-out time, the distance-to-go is also deleted in the block for the synchronous axes.
The alarm is no longer used on P3.2.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Program the axis as positioning axis with axial feed, return stroke or spark-out time.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 auxiliary function of a group programmed repeatedly
%1 = Channel number
%2 = Block number, label
The M and H functions can be divided up as required over machine data in groups in any
variation. Auxiliary functions are thus put into groups that mutually preclude several indi-
vidual functions of one group. Within one group only one auxiliary function is advisable
and permissible.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents