1 Alarms
16120
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16130
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16140
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16150
Parameters:
Definitions:
Reactions:
Remedy:
1-222
Channel %1 block %2 invalid index for tool fine compensation
%1 = Channel number
%2 = Block number, label
Mistake in programming: The 2nd parameter in the PUTFTOC command indicates for
which tool parameter the value is to be corrected (1 - 3 tool lengths, 4 tool radius). The
programmed value is beyond the permitted range.
Permissible values are 1 - 4 if on-line tool radius compensation is allowed (see machine
data ONLINE_CUTCOM_ENABLE), otherwise values 1 - 3.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program: Length 1 - 3 or 4 permissible for radius.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 instruction not allowed with FTOCON
%1 = Channel number
%2 = Block number, label
• Case 1: A plane change is not allowed if the modal G function FTOCON: "fine tool com-
pensation" is active.
• Case 2: Transformation selection is allowed only for zero transformation or transforma-
tion inclined axis, Transmit or Tracyl if FTOCON is active.
• Case 3: Tool change is not allowed with M06 if FTOCON has been active since the last
tool change.
• Case 4: Orientable tool holder is active.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program: Deselect fine tool compensation with FTOCOF.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 FTOCON not allowed
%1 = Channel number
%2 = Block number, label
The tool fine compensation (FTOC) is not compatible with the currently active transforma-
tion.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program: Deselect fine tool compensation with FTOCOF.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid spindle number with PUTFTOCF
%1 = Channel number
%2 = Block number, label
The spindle number programmed for PUTFTOC or PUTFTOCF is beyond the permitted
range for the spindle numbers.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program. Is the programmed spindle number available?