11.02
Reactions:
Remedy:
Program Continuation:
10631
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10650
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10651
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- NC Stop on alarm at block end.
- If the axis is a single axis when this alarm is triggered, the alarm is only effective for this
axis (not effective for e.g. the channel or mode group)
- NC Start disable in this channel.
Program other motion or do not perform overlaid motion.
Clear alarm with the RESET key. Restart part program
Channel %1 axis %2 rests at working area limit %3
%1 = Channel number
%2 = Axis, spindle
%3 = String ( + or - )
The specified axis reaches the working area limitation in JOG mode.
- Alarm display.
Setting data: Check 43420 WORKAREA_LIMIT_PLUS and 43430
WORKAREA_LIMIT_MINUS for the working area limitation.
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 axis %2 incorrect gantry machine data, error code %3
%1 = Channel number
%2 = Axis
%3 = Error no.
An incorrect value was entered in the gantry-specific axial machine data. Further informa-
tion can be derived from the error number.
• Error no. = 1 => either an incorrect gantry unit has been entered or the designation of
the following axis is incorrect.
• Error no. = 2 => master axis has been specified more than once.
- Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Correct the machine data:
MD 37100 GANTRY_AXIS_TYPE
0: No gantry axis 1: Master axis grouping 1 11: Slave axis grouping 1 2: Master axis
grouping 2 12: Slave axis grouping 2 3: Master axis grouping 3 13: Slave axis
grouping 3
Switch control OFF - ON.
Channel %1 illegal gantry configuration. Error code %2
%1 = Channel number
%2 = Reason
The gantry configuration set in the machine data is undefined. Gantry unit and reason for
objection can be found in the transfer parameter.
The transfer parameter is made up as follows.
• %2 = error designation + gantry unit (XX).
• %2 = 10XX => no master axis declared
• %2 = 20XX => no slave axis declared
1 Alarms