Siemens SINUMERIK 840D Series Diagnostics Manual page 539

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
301702
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301703
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301704
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Axis %1 drive %2 track inversion incorrect
%1 = NC axis number
%2 = Drive number
With rotary spindles without EnDat interface operating with enhanced controller modules,
the track inversion (MD_1011.0=1) must not be switched on. Otherwise this error is trig-
gered.
Modify MD 1011: $MD_ACTUAL_VALUE_CONFIG (actual value sensing configuration
IM)
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. With rotary spindles without
EnDat interface operating with enhanced controller modules, the track inversion must be
performed by soldering the A and B tracks differently: A <-> B and A* <-> B*
Switch control OFF - ON.
Axis %1 drive %2 encoder/motor type are not compatible
%1 = NC axis number
%2 = Drive number
If a linear motor was selected (motor selection menu), but no linear scale was configured
(MD_1011.4=0), or if a rotary motor was selected, but a linear scale configured
(MD_1011.4=1), then this error is triggered.
Modify MD 1011: $MD_ACTUAL_VALUE_CONFIG (actual value sensing configuration
IM)
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Encoder type must be
parameterized according to the motor type.
Switch control OFF - ON.
Axis %1 drive %2 pole pair width/division of linear scale (internal) out of range
%1 = NC axis number
%2 = Drive number
With linear motors the pole-pair width and graduations data is used for calculating the
equivalent (internal) pole pair number and (internal) encoder marks. For this it is neces-
sary that the encoder marks correspond to one or x pole pair widths as an integer. This
error message is output if the result is not an integer pole pair width/graduations*x (to
x=16) or if the calculated internal encoder marks value is too high. Absolute interpretation
as an integer if the result is within a +/- 0.001 tolerance.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.