Siemens SINUMERIK 840D Series Diagnostics Manual page 145

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
12540
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12550
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12552
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 Block is too long or too complex
%1 = Channel number
%2 = Block number, label
The maximum internal block length after translator processing must not exceed 256 char-
acters. After editing, for example, several macros in the block or a multiple nesting, this
limit can be exceeded.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Divide up the program block into several subblocks.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 name %3 not defined or option not installed
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
The identifier displayed has not been defined before being used.
Macro: The keyword, to be defined with the DEFINE ... AS ... statement, is missing in one
file:
_N_SMAC_DEF
_N_MMAC_DEF
_N_UMAC_DEF
_N_SGUD_DEF
_N_MGUD_DEF
_N_UGUD_DEF
Variable: DEF statement is missing
Program: PROC declaration is missing
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
• Correct the name used (writing error)
• Check definitions of variables, subroutines and macros
• Declare subroutine with EXTERN, load subroutine to SPF-Dir
• Check interface definition of subroutine
• Check options
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 tool/magazine OEM parameter not defined. Option not set.
Option not set.
%1 = Channel number
%2 = Block number, label
The programmed $TC_... Cx system parameter is not known in the control.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
1 Alarms
1-145

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents