Siemens SINUMERIK 840D Series Diagnostics Manual page 123

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
12000
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12010
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12020
Parameters:
Definitions:
Reactions:
Remedy:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 address %3 programmed repeatedly
%1 = Channel number
%2 = Block number, label
%3 = Source string of the address
Most addresses (address types) may only be programmed once in an NC block, so that
the block information remains unambiguous (e.g. X... T... F... etc. - exception: G and M
functions).
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
• Remove from the NC program addresses that occur more than once (except for those
where multiple value assignments are allowed).
• Check whether the address (e.g. the axis name) is specified via a user-defined variable
(this may not be easy to see if allocation of the axis name to the variable is performed in
the program through computational operations only).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 address %3 address type programmed too often
%1 = Channel number
%2 = Block number, label
%3 = Source string of the address
For each address type, it is defined internally how often it may occur in a DIN block (for
instance, all axes together form one address type for which a block limit also applies).
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
The program information must be split up over several blocks (but make sure that the
functions are of the non-modal type!).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal address modification
%1 = Channel number
%2 = Block number, label
Valid address types are 'IC', 'AC', 'DC', 'CIC', 'CAC', 'ACN', 'ACP', 'CACN', 'CACP'. Not
each of these address modifications can be used for each address type. The Program-
ming Guide specifies which of these can be used for the various address types. If this
address modification is applied to address types that are not allowed, then the alarm is
generated, e.g.:
N10 G02 X50 Y60 I=DC(20) J30 F100
interpolation parameters with DC.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Apply non-modal address modifications only for permissible addresses, in accordance
with the Programming Guide.
1 Alarms