Siemens SINUMERIK 840D Series Diagnostics Manual page 335

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
26017
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
26018
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
26019
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Axis %1 machine data %2[%3] invalid value
%1 = Axis name, spindle number
%2 = String: MD identifier
%3 = Index: MD array index
Machine data includes a value that is not valid.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Repeat entry with correct value and then Reset.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Axis %1 setpoint output drive %2 used more than once
%1 = Axis name, spindle number
%2 = Drive number
A setpoint has been selected more than once. The machine data 30110
$MA_CTRLOUT_MODULE_NR contains the same value for different axes.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Avoid dual assignment of the
setpoint by correcting 30110 $MA_CTRLOUT_MODULE_NR. Also check the selected
bus type $MA_CTROUT_SEGMENT_NR.
Switch control OFF - ON.
Axis %1 encoder %2 measurement not possible with this controller module
%1 = NC axis number
%2 = Encoder number
If the MD $MN_DRIVE_DIAGNOSIS[8] contains a value not equal to zero, then the con-
trol has found at least one control module which does not support measuring. Measuring
was programmed from the part program for the associated axis.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- NC Stop on alarm.
- NC Start disable in this channel.
If possible, modify the measuring motion such that the axis concerned does not have to
travel; do not program this axis in the MEAS block again. However, it is then no longer
possible to query a measured value for this axis. Otherwise, exchange the controller mod-
ule for one that supports measuring. See MD $MN_DRIVE_DIAGNOSIS[8].
Clear alarm with the RESET key. Restart part program