11.02
4320
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4334
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4336
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Axis %1 function %2 %3 and %4 not allowed
%1 = String: Axis identifier
%2 = String: MD identifier
%3 = String: Bit
%4 = String: MD identifier
The functions declared by the specified machine data cannot simultaneously be active for
one axis.
- Mode group not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
Deactivate one of the functions.
Switch control OFF - ON.
Channel %1 The amount of fine correction in parameter %2 of the orientable tool-
holder %3 is too large
%1 = Channel number
%2 = Invalid parameter of the orientable toolholder
%3 = Number of the orientable toolholder
The maximum permissible value of the fine correction in an orientable toolholder is limited
by the machine data $MC_TOCARR_FINE_LIM_LIN for linear variables, and by the
machine data $MC_TOCARR_FINE_LIM_ROT for rotary variables. The alarm can only
occur if the setting data $SC_TOCARR_FINE_CORRECTION is not equal to zero.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Enter a valid fine correction value.
Clear alarm with the RESET key. Restart part program
Channel %1 orientable toolholder no. %2 for orientation transformation %3 does
not exist
%1 = Channel number
%2 = Number of the orientable toolholder
%3 = Number of the orientation transformation that is to be parameterized with the orient-
able toolholder
The orientable toolholder, with whose data the orientation transformation is to be parame-
terized (see machine data $MC_TRAFO5_TCARR_NO_1/2), does not exist.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Enter a valid tool-carrier number.
Clear alarm with the RESET key. Restart part program