Siemens SINUMERIK 840D Series Diagnostics Manual page 199

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Remedy:
Program Continuation:
14761
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14762
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14763
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Please inform the authorized personnel/service department. Only program one help func-
tion per help function group. (For the group division, see the machine manufacturer's pro-
gramming guide).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 motion synchronous action: DELDTG function not allowed
with active tool radius compensation
%1 = Channel number
%2 = Block number, label
Rapid delete distance-to-go for synchronous actions is not allowed with DELDTG when
tool radius compensation is active.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
• Deactivate tool radius compensation before performing rapid delete distance-to-go and
then reselect
or
• as of SW 4.3: "Delete distance-to-go without preparation".
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 too many PLC variables programmed
%1 = Channel number
%2 = Block number, label
The number of programmed PLC variables auxiliary functions has exceeded the maxi-
mum permissible number. The number is set in MD 28150
$MC_MM_NUM_VDIVAR_ELEMENTS.
- Alarm display.
- Interface signals are set.
- NC Stop on alarm.
- Interpreter stop
- NC Start disable in this channel.
Modify part program or machine data.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 too many link variables programmed
%1 = Channel number
%2 = Block number, label
The number of NCU link variables programmed exceeds the maximum limit. The number
is defined in MD $MC_MM_NUM_LINKVAR_ELEMENTS.
- Alarm display.
- Interface signals are set.
- NC Stop on alarm.
- Interpreter stop
- NC Start disable in this channel.
Modify part program or machine data.
Clear alarm with the RESET key. Restart part program
1 Alarms
1-199

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents