1 Alarms
Remedy:
Program Continuation:
12730
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12740
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14000
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14001
Parameters:
Definitions:
1-156
Enter tool clearance for the double turret head in the setting data
$SC_EXTERN_DOUBLE_TURRET_DIST.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no valid transformation machine data parameterized
%1 = Channel number
%2 = Block number, label
The machine data $MC__TRAFO_TYPE_1, $MC_TRAFO_AXES_IN_1[1],
$MC_TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1.
- Alarm display.
- Interface signals are set.
- Correction block
Enter valid transformation identifier for TRACYL in $MC__TRAFO_TYPE_1 and the
rotary axis number in $MC_TRAFO_AXES_IN_1[1] or $MC_TRAFO_AXES_IN_2[1].
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 modal macro call %3 not possible
%1 = Channel number
%2 = Block number, label
%3 = Source string
When calling a modal macro no other modal macro, modal cycle or modal subroutine may
be active.
- Alarm display.
- Interface signals are set.
- Correction block
Modify part program
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 illegal end of file
%1 = Channel number
%2 = Block number, label
Part program was not terminated with M30, M02 or M17. This error is also signalled at the
host if the environment variables NCPROG or NCUPROG have been set to a non-existing
file.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
End part program with M30, M02 or M17 and start part program. Check environment vari-
ables NCPROG and NCUPROG at the host.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 illegal end of block
%1 = Channel number
%2 = Block number, label
After system-internal data manipulation (e.g. when transferring blocks from an external
source) a subfile can end without having LF as the last character.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02