Siemens SINUMERIK 840D Series Diagnostics Manual page 545

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Reactions:
Remedy:
Program Continuation:
301717
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301718
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301719
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Use newer module.
Switch control OFF - ON.
Axis %1 drive %2 SSI transmission timeout
%1 = NC axis number
%2 = Drive number
The SSI transmission must be completed within an NC clock cycle. This is not possible
with its current parameterization.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Either increase the clock cycle length of the NC or increase the SSI transmission rate
(MD_1030 $MD_ACTUAL_VALUE_CONFIG_DIRECT.Bits 14 and 15).
The following transmission rates are possible: 100 kHz, 500 kHz, 1 MHz and 2 MHz.
Notice: It might be possible that the length of the encoder cable does not allow an
increase in frequency!
Switch control OFF - ON.
Axis %1 drive %2 combination of motor/power section invalid
%1 = NC axis number
%2 = Drive number
The motor cannot be operated with the power section selected.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
• Check selection of power section.
• Check motor selection.
• Use valid power section.
Switch control OFF - ON.
Axis %1 drive %2 power section data incomplete
%1 = NC axis number
%2 = Drive number
The data for the power section are incomplete:
• Operation of a power section with an FDD motor requires: MD_1178
$MD_INVERTER_DERATING_SYN (derating factor at 8kHz)
• Operation of a power section with an MSD motor requires: MD_1179
$MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
1 Alarms
1-545

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents