Siemens SINUMERIK 840D Series Diagnostics Manual page 187

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Reactions:
Remedy:
Program Continuation:
14410
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Possible causes of error:
• An axis traversed by the transformation has not been enabled:
• is being used by another channel (-> enable)
• is in spindle mode (-> enable with SPOS)
• is in POSA mode (-> enable with WAITP)
• is concurrent Pos axis (-> enable with WAITP)
• Parameterization via machine data has an error
• Axis or geometry axis assignment to the transformation has an error,
• Machine data has an error (-> modify machine data, cold restart)
Note: Any axes that have not been enabled might be signaled via
EXINAL_ILLEGAL_AXIS = 14092 or BSAL_SYSERRCHAN_RESET = 1011 instead of
EXINAL_TRANSFORM_PARAMETER = 14404.
Transformation-dependent error causes can be in: TRAORI: -
TRANSMIT:
• The current machine axis position is unsuitable for selection (e.g. selection in the pole)
(-> change position slightly).
• Parameterization via machine data has an error.
• Special requirement with respect to the machine axis has not been satisfied (e.g. rotary
axis is not a modulo axis) (-> modify machine data, cold restart).
TRACYL:
• The programmed parameter is not allowed when transformation is selected.
TRAANG:
• The programmed parameter is not allowed when transformation is selected.
• Parameterization via machine data has an error.
• Parameter is faulty (e.g. TRAANG: Unfavorable angle value (-> modify machine data,
cold restart)
Only with active "OEM transformation" compile cycle:
• The axes included in the transformation must be referenced!
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department. Modify part program or
machine data.
Only with active "OEM transformation" compile cycle:
Reference the axes included in the transformation before selecting transformation.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 spline active at geometry axis changeover
%1 = Channel number
%2 = Block number, label
It is not allowed to change the assignment of geometry axes to channel axes in a spline
curve definition.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
1 Alarms