1 Alarms
Remedy:
Program Continuation:
16740
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16750
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16751
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16755
Parameters:
1-228
Assign lead parameters to the axis that determines the velocity.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no geometry axis programmed
%1 = Channel number
%2 = Block number, label
No geometry axis was programmed for tapping (G33) or for rigid tapping (G331, G332).
The geometry axis is, however, essential if an interpolation parameter has been specified.
Example:
N100 G33 Z400 K2 ; thread lead 2mm, thread end Z=400 mm
N200 SPOS=0 ; position spindle in axis mode
N201 G90 G331 Z-50 K-2 ; tapping to Z=-50, counterclockwise
N202 G332 Z5 ; retraction, direction reversal automatic
N203 S500 M03 ; spindle again in spindle mode
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Specify geometry axis and corresponding interpolation parameters.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 axis %3 SPCON not programmed
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
For the programmed function (rotary axis, positioning axis), the spindle must be in posi-
tion control mode.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Program position control of the spindle with SPCON in the previous block.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 spindle/axis %3 SPCOF not executable
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
For the programmed function, the spindle must be in the open-loop control mode. In the
positioning or axis mode, the position control must not be deselected.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Put the spindle into open-loop control mode in the preceding block. This can be done with
M3, M4 or M5 for the relevant spindle.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no stop required
%1 = Channel number
%2 = Block number, label
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents