Siemens SINUMERIK 840D Series Diagnostics Manual page 257

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
17160
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17170
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17180
Parameters:
Definitions:
Reactions:
Remedy:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 no tool selected
%1 = Channel number
%2 = Block number, label
An attempt has been made to access the current tool offset data via the system variables:
$P_AD [n]: Contents of the parameter (n: 1 - 25)
$P_TOOL: Active D number (tool edge number)
$P_TOOLL [n]: Active tool length (n: 1- 3)
$P_TOOLR: Active tool radius
although no tool had been selected previously.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Program or activate a tool offset in the NC program before using the system variables.
Example:
N100 G.. ... T5 D1 ... LF
With the channel-specific machine data:
Modify MD 22550: TOOL_CHANGE_MODE
New tool offset for M function
Modify MD 22560: TOOL_CHANGE_M_CODE
M function with tool change
It is established whether a tool offset is activated in the block with the T word or whether
the new offset values are allowed for only when the M word for tool change occurs.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 number of symbols too large
%1 = Channel number
%2 = Block number, label
The predefined symbols could not be read in during power-up.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 illegal D number
%1 = Channel number
%2 = Block number, label
In the displayed block, access is made to a D number (tool edge number) that is not initial-
ized and therefore is not available.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Check tool call in the NC part program:
• Correct tool edge number D.. programmed? If no tool edge number is specified, then
D1 is automatically active.
• Tool parameters P1 - P25 defined? The dimensions of the tool edge must have been
entered previously either through the operator panel or through the V.24 interface.
Description of the system variables $P_DP x [n, m]