1 Alarms
Remedy:
Program Continuation:
112046
Definitions:
Reactions:
Remedy:
Program Continuation:
112052
Definitions:
Reactions:
Remedy:
Program Continuation:
112057
Definitions:
Reactions:
Remedy:
Program Continuation:
112099
Definitions:
Reactions:
Remedy:
Program Continuation:
112100
Definitions:
Reactions:
Remedy:
Program Continuation:
1-452
By using a smaller milling cutter, the machining could be done with an insertion point.
Internal
Main contour cannot be bypassed
The pocket contour cannot be bypassed with the specified milling cutter.
Residual material will remain.
The program can be started.
This alarm is only a warning.
- Alarm display.
By using a smaller milling cutter, the pocket contour could be bypassed.
Internal
No residual material generated
No residual material was generated. It could be, that there is no more residual material to
machine.
The program can be started.
This alarm is only a warning.
- Alarm display.
No remedy required.
Internal
Programmed helix violates contour
The starting point for helical insertion was so selected, that the helix violates the pro-
grammed contour.
The program can be started.
This alarm is only a warning.
- Alarm display.
Select another starting point; use a smaller helix radius.
Internal
System-error contour pocket
While the contour pocket was being calculated, an error occurred. The contour pocket
cannot be calculated.
The program cannot be started.
- Alarm display.
Make a note of the error text and contact the Siemens AG, A&D MC hotline.
Internal
Error during renumbering. Original state restored.
The soft key "Renumber" was pressed in the program editor. This caused an error during
serial numbering that damaged the program in the memory, making it necessary to reload
the initial program into the memory. The program was not renumbered.
- Alarm display.
Make room in the memory, e.g. by deleting an old program. Select "Renumber" again.
Internal
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents