Definitions:
Reactions:
Remedy:
Program Continuation:
10706
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10707
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10710
Parameters:
Definitions:
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
New movements of a geometry axis which have been added could not be allowed for at
the time of block preparation. It is therefore not certain that the protection zones will not
be violated. This is just a warning message without further reactions.
- Alarm display.
- Interface signals are set.
Take other measures to ensure that the geometry axes motion, including the additional
motion, does not violate the protection zones. (The warning comes nevertheless) or
exclude additional motions.
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 NCK protection zone %2 reached with axis %3 during manual mode
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
The workpiece-related NCK protection zone has been reached with the specified axis.
Note that another tool-related protection zone is still active. The workpiece-related protec-
tion zone can be traversed when the PLC has issued an enable signal.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
Please inform the authorized personnel/service department. Protection zone can be tra-
versed after enable signal from PLC.
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 channel-specific protection zone %2 reached with axis %3 during man-
ual mode
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
The workpiece-related channel-specific protection zone has been reached with the speci-
fied axis. Note that another tool-related protection zone is still active. The workpiece-
related protection zone can be traversed when the PLC has issued an enable signal.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
Please inform the authorized personnel/service department. Protection zone can be tra-
versed after enable signal from PLC.
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 block %2 conflict with centerless grinding
%1 = Channel number
%2 = Spindle number
Centerless grinding is active and a block has been processed that satisfies at least one of
the following conditions:
• G96 active and regulating spindle is master spindle.
• Regulating spindle is in interdependent grouping.
• Axes of centerless transformation overlap with an active transformation and a tool is
active.
• Constant wheel peripheral speed for the regulating spindle is active.
1 Alarms