Chapter 3 Configuration Settings and Display
3.5 Host Interface Management > set iscsi-parameters
-header-digest
-data-digest
-jumbo-frame
-rate
Optional. This parameter specifies whether or not the PDU header's CRC32C checksum is
validated. The initial value is set to disabled. Specify "disable" for the "-header-digest"
parameter to disable the Digest function. When "enable" is specified for the "-header-digest"
parameter, data transfer may fail. If omitted, the existing setting is not changed. This
parameter cannot be specified when the port is set to the RA mode.
enable
PDU header is validated by CRC32C.
disable
PDU header is not validated.
Optional. This parameter specifies whether or not the PDU data's CRC32C checksum is
validated. The initial value is set to disabled. Specify "disable" for the "-data-digest" parameter
to disable the Digest function. When "enable" is specified for the "-data-digest" parameter,
data transfer may fail. If omitted, the existing setting is not changed. This parameter cannot
be specified when the port is set to the RA mode.
enable
PDU data is validated by CRC32C.
disable
PDU data is not validated.
Optional. This parameter specifies whether or not jumbo frame can be specified. If omitted,
the existing setting is not changed. The initial value is set to disabled.
This parameter can be specified as a parameter for the multiple IP address setting.
This parameter cannot be specified when the port is in RA mode or CA/RA auto mode.
enable
The jumbo frame is accepted.
disable
The jumbo frame is not accepted.
To transfer data via Jumbo Frame, make sure the device that is to be connected to the iSCSI
network supports Jumbo Frame.
Optional. This parameter specifies the connection speed of the iSCSI port.
If omitted, the existing setting is not changed. The default value is 10Gbit/s for 10Gbit/s iSCSI,
and 1Gbit/s for 1Gbit/s iSCSI and iSCSI-RA (for connecting older models).
1gauto
1Gbit/s Auto
For 1Gbit/s iSCSI CA/RA auto mode
10gauto
10Gbit/s Auto
For 10Gbit/s iSCSI CA/RA auto mode
1gfull
1Gbit/s Full Duplex
For iSCSI-RA (for connecting older models)
100mfull
100Mbit/s Full Duplex
For iSCSI-RA (for connecting older models)
auto
Auto negotiation
For iSCSI-RA (for connecting older models)
ETERNUS CLI User's Guide