set nas-port
This command configures the parameters that control NAS ports.
This command is unavailable when firmware version V10L20 is being used.
■
Syntax
set nas-port -port
[-mtu mtu_size] [-rate {auto|1g|100mfull}] [-cifs {open | close}] [-nfs {open | close}]
[-rip {open | close}] [-icmp {open | close}]
■
Parameter
-port
-mtu
-rate
-cifs
ports
This parameter specifies the NAS port to be configured based on the format of the host
interface port. Multiple ports can be specified by inserting a comma (,) between them as a
delimiter.
•
Only NAS ports can be specified.
•
If a port bonding setting is configured, member ports can also be specified.
ports
NAS port
Example: -port 000,001
Optional. This parameter specifies the MTU size between 576 and 9000. If omitted, this
parameter is not changed. When using IPv6, specify a value that is 1280 or higher. The default
value is 1500.
mtu_size
MTU size (576 to 9000)
Optional. This parameter specifies the transfer rate of the NAS port. If omitted, this parameter
is not changed. The default value is 1gauto for 1Gbit/s NAS ports, and 10gauto for 10Gbit/s NAS
ports. However, only "auto" can be specified for 10Gbit/s NAS ports.
auto
Automatic
1g
1Gbit/s
100mfull
100Mbit/s Full Duplex (Full duplication)
Optional. This parameter specifies whether the CIFS connection is enabled or disabled. If
omitted, this parameter is not changed. The default value is "open".
open
The CIFS connection is enabled.
close
The CIFS connection is disabled.