Toshiba GR200 Series Instruction Manual page 750

Line differential protection ied
Hide thumbs Also See for GR200 Series:
Table of Contents

Advertisement

Setting
4.2.8
DPSY01(FunctionID:511001 )
Setting items
Commo n
DPSY-NELD
DPSY-TELD
DPSY-TELR
DPSY01-EN
DEV01
DPSY01-DEVNAME
DPSY01-00NAME
DPSY01-01NAME
DPSY01-10NAME
DPSY01-11NAME
DPSY01-UDFNAME
DPSY01-FLTNAME
DPSY01-DEVTYPE
DPSY01A-NOPSG
DPSY01A-NOPSGI
DPSY01A-NCLSG
DPSY01A-NCLSGI
DPSY01B-NOPSG
DPSY01B-NOPSGI
DPSY01B-NCLSG
DPSY01B-NCLSGI
DPSY01C-NOPSG
DPSY01C-NOPSGI
DPSY01C-NCLSG
DPSY01C-NCLSGI
DPSY01-OPC
DPSY01-CLC
DPSY01-SPPEN
DPSY01-UDFEN
DPSY01-UDFTIM
DPSY01-FLTEN
DPSY01-FLTTIM
DPSY01-CTREN
DPSY01-SYNEN
DPSY01-CTRMENU
DPSY01-CTRAHMI
DPSY01-NSLBORD1
DPSY01-NSLBORD2
DPSY01-FSLBORD
DPSY01-OSLBORD
DPSY01-FEXBORD
DPSY01-OEXBORD
Range
Unit
0 - 99
- Number of Event lock detect time
1 - 99
s Timer of detect event lock
1 - 99
s Timer of recovery from event lock
Off / On
- DPSY switch for DEV01
[Preferred text] - item name of DPOSSY_Dev1
[Preferred text] - state name of (0,0)state
[Preferred text] - state name of (0,1)state
[Preferred text] - state name of (1,0)state
[Preferred text] - state name of (1,1)state
[Preferred text] - state name of undefined
[Preferred text] - state name of faulty
1-Pole / 3-Pole
- Device Type
Normally Open Signal of the single-pole or
-
[Preferred signal]
phase A
Off / On
- Signal inverse or not
Normally Close Signal of the single-pole or
-
[Preferred signal]
phase A
Off / On
- Signal inverse or not
- Normally Open Signal of phase B
[Preferred signal]
Off / On
- Signal inverse or not
- Normally Close Signal of phase B
[Preferred signal]
Off / On
- Signal inverse or not
- Normally Open Signal of phase C
[Preferred signal]
Off / On
- Signal inverse or not
- Normally Close Signal of phase C
[Preferred signal]
Off / On
- Signal inverse or not
And / Or
- Normally Open contact grouping
And / Or
- Normally Close contact grouping
Off / On
- Automatic event suppression function
Off / On /
- undefined pallet check function
CHKONLY
0.1 - 100.0
s palette undefined check timer
Off / On /
- faulty pallet check function
CHKONLY
0.1 - 100.0
s palette faulty check timer
Off / On
- control mode (control enable)
APPLY / Bypass - Synchronism Check Apply or Bypass
Off / On
- control by MENU enable
DIR / SBO
- control action(Direct or SBO)by HMI
select binary output read data(DataID)1 for no
-
[Preferred signal]
direction command
select binary output read data(DataID)2 for no
-
[Preferred signal]
direction command
select binary output read data(DataID) for off
-
[Preferred signal]
direction select command
select binary output read data(DataID) for on
-
[Preferred signal]
direction select command
execute binary output read data(DataID) for
-
[Preferred signal]
off direction execute command
execute binary output read data(DataID) for
-
[Preferred signal]
on direction execute command
- 727 -
6F2S1914 (0.49)
Contents
GRL200 (Soft 033 & 037)
Default
Note
10
10
10
Off
DPOS_SYN_Dev1 !
Travelling0
!
Off
!
On
!
Travelling1
!
Undefine
!
Faulty
!
1-Pole
Not Assigned
Off
Not Assigned
Off
Not Assigned
Off
Not Assigned
Off
Not Assigned
Off
Not Assigned
Off
And
Or
Off
Off
30.0
Off
30.0
Off
APPLY
Off
SBO
5110018902011DC0
5110018902011DC0
5110018A02011DC4
5110018602011DC6
Not Assigned
Not Assigned