◆ Signal monitoring points in SPOS01
SPOS01(FunctionID:510001)
Element ID
Name
8301011E9D
SPOS01_CTR_SGN
8401011F77
SPOS01_OFEX_BO
8501011E8F
SPOS01_EX_SFL
8501011F5B
SPOS01_OSL_CS42
8501011F60
SPOS01_FSL_CS19
8501011F65
SPOS01_OSL_CS40
8501011F76
SPOS01_SL_BO_FLG
8601011DC6
SPOS01_OSL_BO_CSF
8601011E91
SPOS01_EX_FFL
8601011E95
SPOS01_CC_SS
8601011F5C
SPOS01_OSL_CS43
8601011F5E
SPOS01_NSL_CS07
8601011F62
SPOS01_SLF_FCT_FLG03
8701011E96
SPOS01_CC_FS
8701011E98
SPOS01_SLF_FCT_EIS
8701011F63
SPOS01_SLF_FCT_FLG04
8801011E9B
SPOS01_CC_ST_ERR
8801011F5D
SPOS01_OSL_CS41
8801011F6B
SPOS01_SLF_FCT_FLG07
8901011DC0
SPOS01_NSL_BO_CSF
8901011F6C
SPOS01_EX_CS01
8901011F72
SPOS01_SLF_FCT_FLG08
8A01011DC4
SPOS01_FSL_BO_CSF
8A01011F61
SPOS01_FSL_CS20
8A01011F6D
SPOS01_EX_CS02
8B01011EA2
SPOS01_CTR_SGU
8B01011F68
SPOS01_EX_CS05
8B01011F6E
SPOS01_EX_CS03
8E01011F57
SPOS01_SLD_TMO
8E01011F67
SPOS01_EX_CS04
8F01011F58
SPOS01_EX_CMP_TMO
◆ Connection point in PLC logic
SPOS01(Function ID: 510001)
Element ID
Name
800101EE32
DEV01_CL_COMMAND
800101EE33
DEV01_CL_INTERLOCK
800101EE30
DEV01_OP_COMMAND
800101EE31
DEV01_OP_INTERLOCK
820101ED50
SPOS01IN_TMP_28
800101EE53
SPOS01IN_TMP_29
810101EE54
SPOS01IN_TMP_30
800101EE61
SPOS01IN_TMP_31
810101EE62
SPOS01IN_TMP_32
800101EE55
SPOS01IN_TMP_33
800101EE56
SPOS01IN_TMP_34
810101EE57
SPOS01IN_TMP_35
820101EE5A
SPOS01IN_TMP_37
830101EE5B
SPOS01IN_TMP_38
Description
SPOS01 control logic stage(unselected)
SPOS01 on/off direction execute binary output signal
SPOS01 execute success signal by fixedlogic
SPOS01 on direction select condition signal 42
SPOS01 off direction select condition signal 19
SPOS01 on direction select condition signal 40
SPOS01 select binary output signal by fixedlogic
SPOS01 on direction select binary output condition signal by fixedlogic
SPOS01 execute fail signal by fixedlogic
TEMP18
SPOS01 on direction select condition signal 43
SPOS01 no direction select condition signal 07
SPOS01 select fail factor signal by fixedlogic 03
TEMP19
SPOS01 select fail factor signal except interlock/synchronism check
SPOS01 select fail factor signal by fixedlogic 04
TEMP20
SPOS01 on direction select condition signal 41
SPOS01 select fail factor signal by fixedlogic 07
SPOS01 select binary output condition signal by fixedlogic
SPOS01 execute condition signal 01
SPOS01 select fail factor signal by fixedlogic 08
SPOS01 off direction select binary output condition signal by fixedlogic
SPOS01 off direction select condition signal 20
SPOS01 execute condition signal 02
SPOS01 control logic stage(under selection)
SPOS01 execute condition signal 05
SPOS01 execute condition signal 03
SPOS01 time out after selected
SPOS01 execute condition signal 04
SPOS01 timeout after execute completion
Description
dev01 close command
dev01 close command with interlock bypass
dev01 open command
dev01 open command with interlock bypass
SPOS01IN_TMP_28
SPOS01IN_TMP_29
SPOS01IN_TMP_30
SPOS01IN_TMP_31
SPOS01IN_TMP_32
SPOS01IN_TMP_33
SPOS01IN_TMP_34
SPOS01IN_TMP_35
SPOS01IN_TMP_37
SPOS01IN_TMP_38