Table 4.2-5 PLC connection points (Interlock for Command 'Closing/Open')
Signal Number
Signal Name
570001 3102011DA2
DPSY01-Open
570001 3102021DA2
DPSY02-Open
570001 3102011DA0
DPSY01-Close
570001 3102021DA0
DPSY02-Close
Table 4.2-6 Mapping points for the reception of control commands
Signal Number
Signal Name
511001 7002016D08
DEV01_CONTROL_REQ
511001 7002026D08
DEV02_CONTROL_REQ
Signal Number
Signal Name
570001 3103011DA2
ASEQ_MULTI_SEL
522001 000A011001
CBK_STATE
522001 000A021001
ICB_STATE
522001 000A031001
SCB_STATE
5A0001 0008001F41
DCB RCV OR
5A0001 0008001F40
Traveling OR
4A0001 8300001B6F
GEN. TRIP
5A0001 3108003F40
SDCEN
5A0101 3100001F43
SERI_ERR
Table 4.2-8 PLC connection points (Input signals for select condition logic)
Signal Number
Signal Name
511001 800531EF40
DPSY01IN_TMP_31
511001 800554EF40
DPSY02IN_TMP_31
511001 800532EF40
DPSY01IN_TMP_32
511001 800555EF40
DPSY02IN_TMP_32
511001 800516EF40
DPSY01IN_TMP_28
511001 800519EF40
DPSY02IN_TMP_28
Table 4.2-9 PLC monitoring points (Output signal for select condition logic)
Signal Number
Signal Name
511001 8002011F5A
DPSY01_SC_ST_ERR
511001 8002021F5A
DPSY02_SC_ST_ERR
511001 8102011F5F
DPSY01_F_QLT_SPP
511001 8102021F5F
DPSY02_F_QLT_SPP
511001 8202011F60
DPSY01_F_BI_ERR
511001 8202021F60
DPSY02_F_BI_ERR
Table 4.2-10 PLC monitoring points (Closing/Open output signals for BIO)
Signal Number
Signal Name
511001 8602011DC6
DPSY01_OSL_BO_FLG
511001 8602021DC6
DPSY02_OSL_BO_FLG
511001 8A02011DC4
DPSY01_FSL_BO_FLG
511001 8A02021DC4
DPSY02_FSL_BO_FLG
Description
DPSY01 interlock condition for Open control.
DPSY02 interlock condition for Open control.
DPSY01 interlock condition for Close control.
DPSY02 interlock condition for Close control.
Description
DPSY01 control command received.(Mapping Data)
DPSY02 control command received. (Mapping Data)
Table 4.2-7 Input signals to condition logic
Description
Automatic sequence control is in progress.
Command Blocking status ( Open / Blocked)
Interlock-Bypassing Switch
Synch-Bypassing Switch
Double Command Blocking(DCB) is in progress.
Travelling events are detected.
General trip
(This is setting of CMNCTRL)
Serious Error detected
Description
DPSY01 additional failure condition(PLC#1)
DPSY02 additional failure condition(PLC#1)
DPSY01 user configurable select condition(PLC#2)
DPSY02 user configurable select condition(PLC#2)
DPSY01 control hierarchy condition(PLC#3)
DPSY02 control hierarchy condition(PLC#3)
Description
DPSY01 Unmatched condition.
DPSY02 Unmatched condition.
Event suppression detected (DPSY01)
Event suppression detected (DPSY02)
BI connection error detected(DPSY01)
BI connection error detected(DPSY02)
Description
DPSY01 select (Closing) command for Binary Output.
DPSY02 select (Closing) command for Binary Output.
DPSY01 select (Open) command for Binary Output.
DPSY02 select (Open) command for Binary Output.
- 684 -
6F2S1914 (0.49)
M/O
N/A
N/A
N/A
N/A
M/O
M
M
M/O
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
M/O
O
O
O
O
M
M
GRL200 (Soft 033 & 037)