Toshiba GR200 Series Instruction Manual page 722

Line differential protection ied
Hide thumbs Also See for GR200 Series:
Table of Contents

Advertisement

Input
Closing control command with ILK† and synchro checks
(PLC#1 connection point)
511001 800201EE35
DEV01_CL_SYNC_INTER
Closing control command with synchro check
(PLC#2 connection point)
511001 800201EE34
DEV01_CL_SYNC
ILK condition ("Closing") passed
DPSY01-Close
From SYNCHK
Closing control command
SYNC01-SYN_CLC
with interlock check
(560001 850B011F59)
point)
(PLC#3 connection
511001 800201EE33
DEV01_CL_INTERLOCK
Closing control command with no check
(PLC#4 connection point)
511001 800201EE32
DEV01_CL_COMMAND
User configurable condition
(PLC#1 connection point)
511001 810201EE57
DPSY01IN_TMP_35
ASEQ function" is in progress
ASEQ_MULTI_SEL
User configurable condition
(PLC#2 connection point)
511001 820201EE5E
DPSY01IN_TMP_44
"DPSY01_OEC_OK_CSF"
(511001 8002011E7F)
Figure 4.2-28 Closing operation logic with PLC in DPSY01
†Note: The ILK function can provide the criteria for operation for "Closing" control.
‡Note: An "operate condition" signal is generated in the operate-condition logic (see
Figure 4.2-31) when Fixlogic is set for scheme switch [DPSY01-LGCTRCON]. If an
alternative "operate-condition" programmed by the user is required in place of
the signal generated by the original operated-condition logic, connect the
alternative "operate-condition" to the logic shown in Figure 1.10-28 using
connection point #1 "User-configurable condition". That is, set the scheme switch
[DPSY01-LGCTRCON] to PLC and use "DPSY01IN_TMP_35".
§Note: The ASEQ function can provide sequential signals for automatic control.
§§Note: The signal "DPSY01_OEX_BO" is issued when Fixlogic is set for scheme switch
[DPSY01-LGCFEXOT]. If the signal to be issued from the logic programmed by the
user instead of the logic shown in Figure 4.2-20, connect the signal "Operate
completed" generated in the user-programmed logic to connection point #2 "User
configurable condition". That is, set the scheme switch [DPSY01-LGCFEXOT] to
PLC and use "DPSY01IN_TMP_44".
*Note: The user can set the type of output signal. When Var is set for scheme switch
Operate logic in DPSY01
DPSY01 function (Function ID: 511001)
Operate Command with ILK†
&
condition & synchro-checking
Operate Command with
&
synchro-checking
Operate Command with ILK†
&
condition
Operate Command without
condition
[DPSY01-LGCTRCON]
Fixedlogic
Operate condition‡
[DPSY01-LGCFEXOT]
Fixedlogic
[DPSY01-PLSM]*
Var
Fix
Detection of state-change in
a device
S
"
"
DPSY01_EX_CMP
R
(511001 8002011E93)
- 699 -
"
DPSY01_OEC_OK_CS"
(511001 8102011E82)
1≥
1≥
&
&
&
&
&
1≥
&
&
6F2S1914 (0.49)
Output
"
DPSY01_OEC_OK_CSF"
(511001 8002011E7F)
[DPSY01-CPW]
1≥
0.1 – 50.0 s
S
R
To BO connection
"DPSY01_OEX_BO" §§
(511001 8202011DD3)
&
Assign to BOs
To "Wait for a command"
"
DPSY01_EX_CMP
(511001 8002011E93)
Operate Completed
"
DPSY01_EX_FFL
[DPSY01-RST]
(511001 8602011E91)
0
t
1.0s- 100.0s
Operate Failed
††
GRL200 (Soft 033 & 037)
"
" ‡‡
PLC