6.3 Appendix C: Stopping Time and Stopping Distance When Safeguard is Open

The stopping time and stopping distance when the safeguard is opened are shown in the graphs for each model.
The stopping time is the length of time corresponding to the "Stopping time" in the figure below. Be sure to confirm that a safe
environment is provided where the robot will be installed and operated.
Symbol
Description
a
Motor speed
b
Safeguard open
c
Time
d
Stopping time
Conditions
The stopping time and stopping distance depend on the parameters (setting values) that were set for the robot. These graphs
show the times and distances for the following parameters.
Accel: 100, 100
Other settings: Default
Explanation of legend
The graphs are displayed for each Weight setting value (at 100%, approx. 66%, and approx. 33% of the maximum payload, and
at the rated load).
Horizontal axis: Arm speed (Speed setting)
Vertical axis: Stopping time and stopping distance at each arm speed
Time (sec): Stopping time (sec)
Distance (deg): J1 and J2 stopping distance (degree)
Distance (mm): J3 stopping distance
When single failures are taken into account, the following adjustments are used.
Stopping distance and angle: Each axis reaches the mechanical stop
Stopping time: Add 500 ms

6.3.1 GX4 Stopping Time and Stopping Distance When Safeguard is Open

GX4-A25***, GX4-B25***: J1
Rev.7
418