NEC UNIVERGE SV8300 Command Manual page 520

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
67
Y
No.
MEANING
21
Programmable list
4
22
Programmable list
5
23
Programmable list
6
24
Programmable list
7
LOCATION DATA ASSIGNMENT
1ST DATA
DATA
MEANING
00
FAX Protocol Pat-
tern No.
NOTE 1:
To avoid the false detection, set the second data to 00 when the locations
(between locations) do not provide FAX over IP feature.
NOTE 2:
When using SIP trunk, set FAX Protocol Pattern by CMBA Y=119.
01
FAX Payload Size
Pattern No.
NOTE:
When using SIP trunk, set FAX Payload size by CMBA Y=120.
08
Minimum value of
jitter buffer
NOTE 1:
When setting CM67 YY=21/22/23/24>08 to other than default, set CM67
YY=21/22/23/24>09 to other than default.
NOTE 2:
Assign the value which does not exceed the maximum value of jitter buffer set
by CM67 Y=21/22/23/24>09.
NOTE 3:
This data is not available when using T.38 UDPTL.
NOTE 4:
Jitter buffer of PZ-64IPLC-A/PZ-128IPLC-A (VoIPDB) is controlled as 200
ms., when minimum value of jitter buffer is set more than 210 ms.
2ND DATA
DATA
MEANING
00
Not detected the FAX
protocol
01
G.711 µ-law
02
G.711 A-law
03
G.726
06
T.38 UDPTL
[8300R3]
NONE
As per Fixed list of
CM67 Y=20
01
10 ms.
04
40 ms.
(10 ms. increments)
NONE
As per Fixed list of
CM67 Y=20
01
10 ms.
30
300 ms.
(10 ms. increments)
NONE
120 ms.
3-464
CM67
: Default
RELATED
COMMAND
CM67 Y=20
NOTE
CM67 Y=20
CM67 Y=21/22/
23/24>09
Continued on next page
NWA-033623-001 Rev.8.1
91ch3005.fm
JANUARY/31/2012

Advertisement

Table of Contents
loading

Table of Contents