COMMAND CODE TITLE:
BA
Y
No.
MEANING
103
Setting of Authentica-
tion password when
registering to/sending
from the SIP server
with character code
(Last 12 characters)
NOTE 1:
When the character code to be set is less than the number of digits necessary, add the character
code FF.
NOTE 2:
You can confirm the password set by this command with CMBA Y=74.
NOTE 3:
Set the second data to NONE for Point-to-Multipoint connection (when CMA7 Y=46 is set to "0").
104
Periodical resending of
provisional response
when receiving to SIP
trunk
[North America
Only]
[8300R4]
NOTE 1:
0 (To provide) or 1 (To provide only when 100rel is provided) should be set when long duration
ringing (3 minutes and more) is provided for incoming calls to SIP trunk from SIP server.
NOTE 2:
When the SIP trunk in communicated system does not support 100rel, if 0 (To provide) is set by
this command, the SIP trunk may remain called when some failure occurs on the SIP trunk in the
communicated system.
105
Request provisional
responses with reliabil-
ity (100rel) when send-
ing from SIP trunk
SIP PROFILE DATA
1ST DATA
DATA
MEANING
00
Profile number
for control packet
31
RESET
00
Profile number
for control packet
31
RESET
00
Profile number
for control packet
31
RESET
2ND DATA
DATA
XXX...X
Password
(16 digits, 8 charac-
ters fixed)
NONE
No data
0
To provide
1
To provide only when
100rel is provided
3
Not provided
0
Available (Supported
header and Require
header)
1
Available (Supported
header)
3
Not available
3-630
: Default
RELATED
COMMAND
MEANING
CMA7 Y=71
CMBA Y=74,
75, 102
See
Character
Code Table in
CM77.
CMA7 Y=71
CMA7 Y=71
Continued on next page
NWA-033623-001 Rev.8.1
JANUARY/14/2011
CMBA