[Cm4A] Day/Night Mode Change By System Clock, Automatic Rc/ Dnd Mode Select By System Clock - NEC UNIVERGE SV8300 Command Manual

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
4A
FUNCTION:
This command is used to assign the schedule of Day/Night Mode Change and Automatic RC/DND
Mode select by System Clock.
PRECAUTION:
(1)
For Automatic Day/Night Mode Change
• For the normal operation of Automatic Day/Night Mode Change by System Clock, Day/Night
Mode Change by the external key, by service access code or feature key, by Attendant Console
should not be executed.
• Automatic Day/Night Mode Change can be set to each tenant.
• Automatic Day/Night Mode Change can be set, whether two kinds of mode (Day/Night Mode)
or four kinds of mode (Day/Night Mode/Mode A/Mode B) is set.
• If the following settings is executed, Automatic Day/Night Mode Change may not be operated
correctly.
- Day/Night Mode is changed by function keys.
- Day/Night Mode is changed by external keys.
- Day/Night Mode is changed by Attendant console.
• Trunk Restriction Class can be changed according to the schedule of Day/Night Mode Change
by System Clock. This is assigned by CM65 Y=36 and available for two kinds of mode (Day
Mode/Night Mode only).
• Automatic Day/Night Mode Change is effective 4-8 seconds later after the command setting.
(2)
For Automatic RC/DND Mode Select
• Automatic RC/DND Mode Select can not be set a calendar to each tenant.
• RC/DND Mode Select of each terminal by function key can be set while Automatic RC/DND
Mode Select is operating.
• Automatic RC/DND Mode Select is effective about 25 seconds later after setting the command.
ASSIGNMENT PROCEDURE:
ST
+ 4AYY +
DE
DAY/NIGHT MODE CHANGE BY SYSTEM CLOCK, AUTOMATIC RC/
DND MODE SELECT BY SYSTEM CLOCK
1ST DATA
+
(1-4 digits) +
DE
2ND DATA
+
+ EXE
(1/2 digits)
3-403
CM4A
NWA-033623-001 Rev.8.1
91ch3004.fm
JULY/17/2009

Advertisement