COMMAND CODE TITLE:
FA
FUNCTION:
This command is used to read the apparatus information of IP Station.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
ST +
FAYY/YYYY
DATA TABLE:
Y
No.
MEANING
00
Read the IP Station
firmware version
IP STATION APPARATUS INFORMATION
1ST DATA
+ DE
+
(1-15 digits)
1ST DATA
DATA
MEANING
X
IP Station No.
XXXXXXXX
+
DE
DATA
AABB
CCDD
0000
AABB
3-705
INDICATION
MEANING
Current firmware version of the IP
Station (for SIP Multiline Terminal)
AABBCCDD:
AA: Integral No. (00-99)
BB: First decimal No. (00-99)
CC: Second decimal No. (00-99)
DD: Third decimal No. (00-99)
Current firmware version of the IP
Station (for IP Multiline Terminal)
0000AABB:
AA: Integral No. (00-99)
BB: First decimal No. (00-99)