NEC UNIVERGE SV8300 Command Manual page 75

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
04
Y
No.
MEANING
01 Setting of System
Services (b)
SETTING OF SYSTEM SERVICES
1ST DATA
DATA
MEANING
10
Control method for Hotel
Feature
NOTE:
Set this data to "0" for PMS and Hotel/Motel Front Desk Instrument/DSS con-
sole synchronization when using 8300R5 software or later.
11
Partition of Conference
(built-in CPU)
[8300R2]
12
Store of SMDR billing
data
[8300R3]
NOTE 1:
After change this data, execute the SRAM memory clear by CM00>02 or
CM00>11. When VRS built-in CPU is used and this data is changed 3 to 1,
SRAM memory clear is not required.
NOTE 2:
Execute the SRAM area all clear by CM00>02 (SRAM area all clear) before
change this data, when call charge printout is executed.
NOTE 3:
When this data is set to default data, all the SMDR billing data is cleared by
System Reset.
NOTE 4:
When this data is set to "0" (SRAM [Maximum 27000 calls]), SRAM cannot
be used for Voice Response System (VRS).
14
Select of PMS Interface
[8300R3]
2ND DATA
DATA
0
PMS, PMS with Hotel/
Motel Front Desk
Instrument, DSS Con-
sole
1
Hotel/Motel Front Desk
Instrument, DSS Con-
sole, Printer
3
No data
0
Four 8-party conference
groups (8+8+8+8)
2
Two 16-party confer-
ence groups (16+16)
3
One 32-party conference
group (32)
0
SRAM (Maximum
27000 calls)
1
SRAM (Maximum
12000 calls)
3
SDRAM (1023 calls)
0
RS-232C
3
TCP/IP
3-19
: Default
RELATED
COMMAND
MEANING
CM08>896
Continued on next page
NWA-033623-001 Rev.8.1
91ch3001.fm
JANUARY/31/2012
CM04

Advertisement

Table of Contents
loading

Table of Contents