ATTENDANT OVERRIDE

PROGRAMMING
START
CM08
Provide the system with ATTENDANT
OVERRIDE.
Specify the interval of the Warning Tone sent
to the connected parties.
Specify whether the Warning Tone is sent to
the outside party.
CM12
Assign Service Restriction Class A to each
station.
CM15
Allow Attendant Override called side in the
Service Restriction Class A assigned by CM12
Y=02.
CM20
Assign the access code for Individual Trunk
Access.
CM30
Assign the Trunk Identification Code to each
trunk.
NOTE:
A
DESCRIPTION
By loading the Resident System
Program, Trunk Identification
Codes are assigned as follows:
1XXX
XXX: 000-255 (Trunk number)
(1)
012
(2)
1 : Available
(1)
045
(2)
0 : Only once
1 : Every 4 seconds
(1)
076
(2)
0 : To send
1 : Not sent
Y=02
(1)
X-XXXXXXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class A
Y=09
(1)
00-15: Service Restriction Class A as-
signed by CM12 Y=02
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A081: Individual Trunk Access
Y=19
(1)
000-255: Trunk No.
(2)
XXXX: Trunk ID Code